High Quality HV Power Supply, Small X Ray Machine , Radiography Machine Suppliers in China

Home > Products > HV Power Supply > vp 33312 vp 33314 high voltage power supply for toshiba 5804 5761 5764 5830 image intensifier

vp 33312 vp 33314 high voltage power supply for toshiba 5804 5761 5764 5830 image intensifier

Product Description

Application

High Voltage Power Supply for Image Intensifier


NK5761HD-P4/P7 high voltage power supply is designed for the replacement of Toshiba VP33312 VP33314 high voltage power supply. 


It can be used on Toshiba E5804, E5761, E5764, E5830 etc image intensifiers.


Its shape, input and output characters are the same with the original, which can completely replace the original. 


It has much more stability and reliability than the original. The power supply includes main power supply plate (installed at the image intensifier inside) and adjustment plate two parts.


Product Description

It must pay attention as follows before installation!

1.It must ensure the x-ray image intensifier tube is normal working, without the tube discharge, electricity leakage, air admission, and the input screen damage phenomenon.

2.It had better use alcohol to clean the image intensifier high voltage cable connection terminal and dry it in the air. If the high voltage cable connection terminal is not clear, it may cause the discharge after insert into the high voltage power supply and cause the high voltage power supply damage.

3.It must ensure the image intensifier high voltage cable connection terminal insert into the bottom of the HV and fix the high voltage cable. Because if the high voltage cable is loosen, it will cause spark phenomenon and make the high voltage power supply damage.

4.When finish the above steps, but the HV of high voltage power supply still have little discharge phenomenon. It needs to disconnect the power and then pull out the high voltage cable and lay on some silicone grease, and then connect it again. The discharge phenomenon will disappear.

5.It must under dry air environment to install.

Replacement Method

(1)  Open image intensifier and remove the the main power supply plate connection wires, then use the new main power supply plate to replace the bad one, and fix it according to the original installation method.

(2)  Insert the image intensifier HV cable into the high voltage power supply HV terminal. It must insert the HV cable to the bottom!

(3)  Insert the image intensifier G2 wire into the high voltage power supply G2 terminal.

(4)  Connect the adjustment plate PV with G1.

(5)  Connect the PV grounding terminal with the main power supply plate grounding.

(6)  Connect the image intensifier cathod E with the PC. Connect the image intensifier grounding wire with the main power supply plate grounding.

(7)  Connect DC24V power supply, the red wire is +24V, the black wire is -24V.

Attention: P1 controls Center Focusing; P2 Control Edge Focusing


Adjustment Method

After make correct connection, if the image not clear, first make adjustment of P1 potentiometer (center focusing) until the image become to clear, then make fine adjustment of P2 potentiometer (edge focusing) till the image become most clear.


Order & Payment

(1) Just tell us your original image intensifier brand and model, it had better to send us the pictures of the old or bad high voltage power supply label, it is necessary for us to judge the replacement one type.


(2) After confirmation the replacement type, we will send you our best factory quotation and send you the proforma invoice.

(3) You could make payment by TT, Western Union, Paypal or Visa Credit card according to the PI.

(4) We will send the product to you within 3 days after receiving the payment.

(5) When you receive the product, if you have any problems for installation, we will arrange our engineer to offer you the technical support on line.


Our Service
√ Original manufacturer of image intensifier TV system and x-ray machine accessories for more than 16 years.

√ Customers could find all kinds of x-ray machine parts here.

√ Offer 5 years after sale service.

√ Promise super product quality with best price and service.

√ Support the third part inspection before delivery.

√ Ensure the shortest delivery time.
Packing & Delivery
Packaging
Size
24 cm(L) * 20cm (W) * 12cm (H)
Weight
1kg



Packaging Details
The normal package is carton.

Adopt waterproof protection.

Adopt necessary cushioning processing.


Related Products

Hand Switch for C arm R&F X Ray Machine

91.8% Response Rate

Medical X Ray Machine Cables 75kv 90kv

91.8% Response Rate

7195 High Voltage Power Supply

91.8% Response Rate

Contact us if you need more details on Vp 33312 High Voltage Power Supply. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Vp 33314 High Voltage Power Supply、5804 5761 5830 Image Intensifier. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : HV Power Supply